From: Highly sensitive ultrasound detection using nanofabricated polymer micro-ring resonators
Fabrication method | Substrate | Core material | Detector diameter | Waveguide dimension (width × height) | Q-factor | Working wavelength | Frequency bandwidth | NEP | PA imaging resolution | Application | Year [Refs] |
---|---|---|---|---|---|---|---|---|---|---|---|
NIL SiO2 on Si mold | SiO2 on Si | PS | 60 μm (racetrack) | 2.3 μm x 1.8 μm | 1.0 × 103 | 1.55 μm | 10 MHz | N/A | N/A | US | 2004 [49] |
SiO2 on Si | PS | 95 μm | 2.4 μm x 1.85 μm | 6.0 × 102 | 1.55 μm | 40 MHz | 150 kPa | N/A | US | 2007 [37] | |
SiO2 on Si | PS | 100 μm | 2 μm x 2 μm | 6.0 × 103 | 1.55 μm | 90 MHz | 230 Pa | N/A | US | 2008 [50] | |
SiO2 on Si | PS | 100 μm | 2 μm x 2 μm | 5.0 × 103 | 1.55 μm | 70 MHz | 4.1 kPa | Lateral: 150 μm Axial: 90 μm | PAT | 2008 [51] | |
SiO2 on Si | PS | 100 μm | 2 μm x 2 μm | 6.0 × 103 | 1.55 μm | 16 MHz | 111.4 Pa | Lateral: 209 μm Axial: 81 μm | PAT | 2009 [52] | |
SiO2 on Si | PS | 100 μm | 2 μm x 2 μm | 6.0 × 103 | 1.55 μm | 74 MHz | 200 Pa | Lateral: 146 μm Axial:50 μm | PAT | 2011 [57] | |
Quartz | PS | 100 μm | 2 μm x 2 μm | 5.0 × 103 | 1.55 μm | 51 MHz | N/A | Transverse:750 μm Radial: 21 μm | PA endoscopy | 2011 [53] | |
NIL Si mold | SiO2 on Si | PS | 90 μm | N/A | 1.5 × 105 | 1.55 μm | 74 MHz | 88 Pa | N/A | US | 2011 [28] |
SiO2 on Si | PS | 60 μm 40 μm | 1 μm x 1.4 μm | 4.0 × 105 7.0 × 104 | 780 nm | 74 MHz | 21.4 Pa 100 Pa | Axial: 75 μm Axial: 50 μm | PAT | 2011 [29] | |
SiO2 on Si | PS | 40 μm | 1 μm x 1.4 μm | 7.0 × 104 | 780 nm | 74 MHz | 100 Pa | Lateral: 55 μm Axial:50 μm | PAT | 2011 [57] | |
SiO2 on Si | PS | 60 μm | 1 μm x 1.4 μm | 3.0 × 105 | 780 nm | 74 MHz | 29 Pa | Lateral: 5 μm Axial: 8 μm | PAM | 2011 [58] | |
SiO2 on Si | PS | 60 μm | 1 μm x 1.4 μm | 3.0 × 105 | 780 nm | 74 MHz | 29 Pa | Lateral: 17.5 μm Axial: 20 μm | PAM | 2012 [59] | |
SiO2 on Si | PS | 95 μm | 2.4 μm x 1.85 μm | N/A | 1.55 μm | 28 MHz | N/A | Lateral: 305 μm Axial: 169 μm | PA-US | 2012 [61] | |
SiO2 on Si | PS | 60 μm | 1 μm x 1.4 μm | 1.3 × 105 | 780 nm | 350 MHz | 105 Pa | Lateral: N/A Axial: 2.7 μm | PAM | 2014 [60] | |
EBL | Quartz | SU-8 | 60 μm | 0.8 μm x 0.8 μm | 1.0 × 104 | 780 nm | 140 MHz | 6.8 Pa | Lateral: N/A Axial: 5.3 μm | PAM | 2014 [30] |
Quartz | SU-8 | 60 μm | 0.8 μm x 0.8 μm | 4.8 × 103 | 780 nm | 250 MHz | 352 Pa | Tangential: 15.7 μm radial: 4.5 μm Axial: 16 μm | PA endoscopy | 2014 [33] | |
Quartz | SU-8 | 60 μm | 0.8 μm x 0.8 μm | 1.0 × 104 | 780 nm | 280 MHz | 6.8 Pa | Lateral: 0.73 μm Axial: 2.12 μm | Multimodal PAM | 2015 [32] | |
MPL | Quartz | IP-Dip | 60 μm | 4 μm (diameter) | 3.4 × 103 | 1.55 μm | 10 MHz | N/A | N/A | US | 2017 [46] |
sNIL PDMS mold | Quartz | PS | 80 μm | 0.8 μm x 0.8 μm | 1.4 × 105 | 780 nm | 166 MHz | 0.49 Pa | Axial: 3.57 μm | PAM | 2019 [34] |
Quartz | PS | 80 μm | 0.8 μm x 0.8 μm | 4.6 × 104 | 780 nm | 23 MHz | 81 Pa | Lateral: 114 μm Axial :57 μm | PACT | 2022 [35] |