Table 1 Summary of nanofabrication methods of polymer MRRs for optical ultrasound detectors and their key parameters

From: Highly sensitive ultrasound detection using nanofabricated polymer micro-ring resonators

Fabrication method

Substrate

Core material

Detector diameter

Waveguide dimension (width × height)

Q-factor

Working wavelength

Frequency bandwidth

NEP

PA imaging resolution

Application

Year [Refs]

NIL

SiO2 on Si mold

SiO2 on Si

PS

60 μm (racetrack)

2.3 μm x 1.8 μm

1.0 × 103

1.55 μm

10 MHz

N/A

N/A

US

2004 [49]

SiO2 on Si

PS

95 μm

2.4 μm x 1.85 μm

6.0 × 102

1.55 μm

40 MHz

150 kPa

N/A

US

2007 [37]

SiO2 on Si

PS

100 μm

2 μm x 2 μm

6.0 × 103

1.55 μm

90 MHz

230 Pa

N/A

US

2008 [50]

SiO2 on Si

PS

100 μm

2 μm x 2 μm

5.0 × 103

1.55 μm

70 MHz

4.1 kPa

Lateral: 150 μm

Axial: 90 μm

PAT

2008 [51]

SiO2 on Si

PS

100 μm

2 μm x 2 μm

6.0 × 103

1.55 μm

16 MHz

111.4 Pa

Lateral: 209 μm

Axial: 81 μm

PAT

2009 [52]

SiO2 on Si

PS

100 μm

2 μm x 2 μm

6.0 × 103

1.55 μm

74 MHz

200 Pa

Lateral: 146 μm

Axial:50 μm

PAT

2011 [57]

Quartz

PS

100 μm

2 μm x 2 μm

5.0 × 103

1.55 μm

51 MHz

N/A

Transverse:750 μm

Radial: 21 μm

PA endoscopy

2011 [53]

NIL

Si mold

SiO2 on Si

PS

90 μm

N/A

1.5 × 105

1.55 μm

74 MHz

88 Pa

N/A

US

2011 [28]

SiO2 on Si

PS

60 μm

40 μm

1 μm x 1.4 μm

4.0 × 105

7.0 × 104

780 nm

74 MHz

21.4 Pa

100 Pa

Axial: 75 μm

Axial: 50 μm

PAT

2011 [29]

SiO2 on Si

PS

40 μm

1 μm x 1.4 μm

7.0 × 104

780 nm

74 MHz

100 Pa

Lateral: 55 μm

Axial:50 μm

PAT

2011 [57]

SiO2 on Si

PS

60 μm

1 μm x 1.4 μm

3.0 × 105

780 nm

74 MHz

29 Pa

Lateral: 5 μm

Axial: 8 μm

PAM

2011 [58]

SiO2 on Si

PS

60 μm

1 μm x 1.4 μm

3.0 × 105

780 nm

74 MHz

29 Pa

Lateral: 17.5 μm

Axial: 20 μm

PAM

2012 [59]

SiO2 on Si

PS

95 μm

2.4 μm x 1.85 μm

N/A

1.55 μm

28 MHz

N/A

Lateral: 305 μm

Axial: 169 μm

PA-US

2012 [61]

SiO2 on Si

PS

60 μm

1 μm x 1.4 μm

1.3 × 105

780 nm

350 MHz

105 Pa

Lateral: N/A

Axial: 2.7 μm

PAM

2014 [60]

EBL

Quartz

SU-8

60 μm

0.8 μm x 0.8 μm

1.0 × 104

780 nm

140 MHz

6.8 Pa

Lateral: N/A

Axial: 5.3 μm

PAM

2014 [30]

Quartz

SU-8

60 μm

0.8 μm x 0.8 μm

4.8 × 103

780 nm

250 MHz

352 Pa

Tangential: 15.7 μm

radial: 4.5 μm

Axial: 16 μm

PA endoscopy

2014 [33]

Quartz

SU-8

60 μm

0.8 μm x 0.8 μm

1.0 × 104

780 nm

280 MHz

6.8 Pa

Lateral: 0.73 μm

Axial: 2.12 μm

Multimodal PAM

2015 [32]

MPL

Quartz

IP-Dip

60 μm

4 μm (diameter)

3.4 × 103

1.55 μm

10 MHz

N/A

N/A

US

2017 [46]

sNIL

PDMS mold

Quartz

PS

80 μm

0.8 μm x 0.8 μm

1.4 × 105

780 nm

166 MHz

0.49 Pa

Axial: 3.57 μm

PAM

2019 [34]

Quartz

PS

80 μm

0.8 μm x 0.8 μm

4.6 × 104

780 nm

23 MHz

81 Pa

Lateral: 114 μm

Axial :57 μm

PACT

2022 [35]

  1. N/A: not available. US: ultrasound detection